• Home • Up • Products • Feedback • Search • Cable Installation • About •

Paradyne 3610 Series

 

RB DATA SYSTEMS, INC.

(212) 757-0080

 

 

 

COMSPHERE 3610 Series Data Service Units (DSUs) are highly reliable, state-of-the-art

products ideal for today's network-managed digital environments. The COMSPHERE 3610 DSU

enables users to take maximum advantage of today’s digital services.

Operating in conjunction with Paradyne's COMSPHERE 6700 Series Network Management

System (NMS), the COMSPHERE 3610 Series DSU provides a comprehensive network

management solution that is both flexible and affordable. Network management options are

expanded to include SNMP when used with the COMSPHERE 6700 and optional SNMP agent

software. The series uses an advanced diagnostic technique to provide comprehensive network

monitoring, testing and control over point-to-point and multipoint circuits. Network managers are

provided with a comprehensive feature set and options that combine to maximize network

availability, reduce equipment costs, and provide fully integrated network management control. The

COMSPHERE 3610 also provides an SNA Diagnostic Interface for enhanced NetView LPDA-2

interoperability. Low-cost device control is provided via an ASCII terminal using the COMSPHERE

3610 ASCII support feature. This feature is available only in the standalone version.

COMSPHERE

3610 SERIES DSUs

 

3610 SERIES

• FULLY INTEGRATED NETWORK MANAGEMENT

CAPABILITIES FOR COMPREHENSIVE

TESTING, MONITORING AND CONTROL

• ASCII TERMINAL INTERFACE ALLOWS AN

ASCII TERMINAL FULL DIAGNOSTIC AND

CONFIGURATION CONTROL OF

STANDALONE VERSIONS ONLY

• NETVIEW LPDA-2 MANAGEMENT

• POINT-TO-POINT AND MULTIPOINT

NON-DISRUPTIVE DIAGNOSTICS

• DDS RATES FROM 2.4 TO 64 Kbps

• USER-CONFIGURABLE DATA RATES FROM

150 TO 56,000 bps AND 64,000 bps (CLEAR

CHANNEL)

• RATE ADAPTATION FOR POINT-TO-POINT

AND MULTIPOINT CIRCUITS

• AVAILABLE IN STANDALONE AND CARRIER

CARD VERSIONS

• CO-RESIDENT EIA-232D/V.24 AND CCITT V.35

INTERFACES

 

F E A T U R E S

(continued on page 2)

™

3610 SERIES SPECIFICATIONS

DSU Module

Digital data services provided by Regional Bell

Operating Companies (RBOCs) and Local

Exchange Carriers (LECs)

Data Rate

Synchronous terminal rates of 2,400, 4,800,

9,600, 19,200, 56,000 and 64,000 bps

Elastic Storage Buffer

+/- 8 bits

Timing

DDS, internal, external or receiver

Data Format

Serial, synchronous, protocol-independent,

binary data in full or half-duplex operation

Data Encoding

Bipolar return to zero; complies with AT&T

Technical Reference 62310 - 1987

Transmit Levels

19,200 bps: -10, 0, or +6 dBm

9,600 bps: 0 dBm

All other speeds: +6 dBm

Receiver Sensitivity Level

-42 dBm at 56,000 bps

Transmit and Receive Impedances

135 ohms nominal

Digital Network Interface

3610 Standalone: 8-pin modular jack, USOC

RJ48S

3611 Carrier Card: 50-pin connector, USOC

RJ48T (one for slots 1-8, one for slots 9-16)

Network Management System

Compatibility

COMSPHERE 6700 (6800) Series NMS

Device control via ASCII interface

(Standalone only)

DTE Interface

25-pin subminiature connector (female)

EIA-232D/CCITT V.24 (ISO 2110)

34-pin connector (female)

CCITT V.35 (ISO 2593)

AC Power Requirements

3610 Standalone:

90-132 VAC, 60 Hz +/-3Hz, 0.15 amp:

13.4 watts max at 115 VAC

3611 Carrier Card:

Supplied by carrier: 80 watts max

3000 Series Carrier fan module:

Supplied by carrier: 45 watts

Environment

Operating temperature: 32ฐ F (0ฐ C) to 122ฐ F

(50ฐ C)

Storage temperature: -4ฐ F (-20ฐ C) to 158ฐ F

(70ฐ C)

Relative humidity: 5% to 90%

non-condensing

Shock and vibration: withstands normal

shipping and handling

Heat Dissipation at 115 VAC

3610 Standalone

32.4 BTU/hr max

3000 Series Carrier (16 DSUs plus SDU and

fan module) 563 BTU/hr max

Dimensions

3610 Standalone:

Height: 2.13 inches (5.4 cm)

Width: 7.63 inches (19.4 cm)

Depth: 13.4 inches (34.0 cm)

3611 Carrier Card:

Height: 7.13 inches (18.1 cm)

Width: 0.9 inches (2.3 cm)

Depth: 13.4 inches (34.0 cm)

3000 Series Carrier:

Height: 10.5 inches (26.7 cm)

Width: 19.0 inches (48.3 cm)

Depth: 14.0 inches (35.6 cm)

Weight

3610 Standalone: 5 lb. (2.3Kg)

3611 Carrier Card: 1.5 lb (0.7Kg)

3000 Series Carrier: (16 DSUs plus

SDU and fan): 70 lbs. (31.8 Kg)

Regulatory Approvals

FCC Part 15 - Class A digital device

FCC Part 68 - AW292J-61661-DD-N

3610 Standalone:

Listed UL 1950

Certified CSA C22.2, No. 220-M1986

3611 Carrier Card, 3000 Series Carrier:

Recognized Component UL 1950

CSA Safety - Certified CSA 22.2

No. 950-M89

3610 and 3611:

CSA Emissions - Class A digital apparatus

Bell Canada - "DCTE Specifications,"

July 1989, Issue 1

 

F E A T U R E S

3610 SERIES

• AUTO RATE DETECTION

• CROSS PAIR DETECTION

• EXTENDED RANGE SUPPORT

• POINT-TO-POINT OR MULTIPOINT

OPERATION

• STANDALONE VERSION FEATURES A

USER-FRIENDLY FRONT PANEL WITH A

TWO-LINE, 16-CHARACTER PER LINE,

MENU-DRIVEN DISPLAY WITH KEYPAD

FOR CONTROL OF LOCAL AND REMOTE

DEVICES

• FULL COMPLEMENT OF LOCAL AND

REMOTE LOOPBACKS

• INTEGRAL 511 TEST-PATTERN GENERATOR

AND COMPARATOR

• THREE POWER LEVELS FOR COMPATIBILITY

WITH RBOC AND LOCAL EXCHANGE

CARRIER FIXED DATA RATES OF 19,200 bps

• ELASTIC STORE FEATURE FOR EXTENDED

CIRCUIT APPLICATIONS

• POINT-TO-POINT OPERATION AS A LIMITED

DISTANCE MODEM

• ASYNCHRONOUS OR SYNCHRONOUS

SUPPORT ON ALL PORTS

(continued from page 1)

2

O P T I O N A L F E A T U R E S

TDM/MCMP

• MULTICHANNEL MULTIPOINT (MCMP)

FUNCTION THAT ALLOWS UP TO SIX

NON-DISRUPTIVE, PROTOCOL

INDEPENDENT DATA PATHS OVER A

SINGLE MULTIPOINT CIRCUIT

• STANDALONE ONLY VERSION HAS 'FLEX'

MUX FUNCTION--2 OR 6 PORTS: 1 OR 5

PORTS (DB25) IN THE EXPANDED

HOUSING CONFIGURED AS EITHER

ELECTRICAL EIA-232 OR V.35, AND 1 PORT

ON THE BASE DSU AS EITHER EIA-232D OR

V.35 CONNECTOR

• OPERATIONAL MODES OF MCMP, TDM,

DSD AND MULTIPOINT DIAL RESTORAL

BRIDGE

• ONE- OR TWO-PORT SHARING GROUPS

THAT PROVIDE UP TO 6 PORTS

• AUTOMATIC TDM RECONFIGURATION TO A

REDUCED DATA RATE UPON ENTRY INTO

DIAL RESTORAL MODE

• INDIVIDUAL PORT TESTS AND

LOOPBACKS

• ELASTIC STORE FEATURE PROVIDES

A BUFFER ON EACH PORT TO SUPPORT

DIGITAL OR ANALOG EXTENDED CIRCUITS

• DIGITAL BRIDGE FOR MULTIPOINT DIAL

RESTORAL

• CONCURRENT OPERATION OF TDM AND

DSD MODES

TIME DIVISION MULTIPLEXER (TDM)/MULTICHANNEL MULTIPOINT

(MCMP) OPTION

Increased flexibility in network design and implementation is an important advantage of the Time

Division Multiplexer/Digital Sharing Device (TDM/DSD 'Flex') option, while providing cost-effective

data networking alternatives. The TDM/DSD 'Flex' function improves the use of digital facilities

through bandwidth control and allocation. The TDM/DSD 'Flex' option can be controlled by the 6700

Series NMS, the Shared Diagnostic Control Panel (SDCP), or the COMSPHERE 3610 front panel.

TDM

The TDM will multiplex up to six channels onto a single point-to-point digital facility. Configured

as a DSD, the DSU allows up to six polled-protocol devices to share a single point-to-point or multipoint

digital facility. Configured as a host port-sharing device, the TDM/DSD 'Flex' shares up to six

host ports for the primary purpose of disaster recovery. Three ports are used for the primary data path

and three ports for automatic 'hot' spare during a front end port failure. The versatile TDM/DSD 'Flex'

option when configured with the Dial Backup Module (DBM) card version, serves as the digital bridge

for multipoint single-call dial restoral applications.The TDM/DSD 'Flex' option requires an expanded

housing to the COMSPHERE 3610 standalone version and a separate card slot in the COMSPHERE

3000 Series Carrier with the COMSPHERE 3611 card version.

MCMP

The MultiChannel MultiPoint (MCMP) option builds on TDM/DSD features by supporting all

TDM/DSD functions while adding MCMP functions to create one of the most powerful and flexible

DSUs in the industry. The sophisticated MCMP option uses a patented technology to consolidate

multiple applications and protocols over a single multipoint digital facility. Up to six individual data

channels can be configured for your multipoint circuit. Each channel is non-interfering with other

channels and protocol insensitive. These characteristics broaden the number of applications available

to allow both point-to-point and multipoint applications to work on the same mulitpoint circuit.

MCMP comes in both a two- and six-port standalone version that can be mixed on the same

circuit. This means you do not have to buy a six-port version for all remote sites (when all you need

is a two-port version at some sites and a six-port version at other sites). The unique any port to any

port mapping feature from the central site DSU to remote DSUs, adds flexibility to your configuration

choices. This unique mapping feature allows remote site configurations to support both MCMP and

DSD applications. As with the TDM/DSD option, up to two DSD groups can be configured or use the

digital bridge mode for multipoint single-call dial restoral applications.

™

(continued on page 4)

3

DIAL BACKUP MODULE

SPECIFICATIONS

ISDN BRI Module

Application

Full-duplex data transmission via ISDN BRI U-Interface for point-to-point

or multipoint facilities. Integrated NT1 included.

Modulation and Frequency

2B1Q line coding with 4-level pulse amplitude modulation (PAM) at 80K

baud

Channel Equalization

Receiver: Automatic adaptive equalizer with echo cancellation

Communication Line

2-wire BRI ISDN line

Data Rates

56 and 64 Kbps (Note that ISDN DBM or DBM-I use proprietary rate

adaption to support data rates of less than 64 Kbps.)

DBM Interface

Compatible with 3600 Series 2-wire and 4-wire Switched 56 DBMs

Receive Interface

Dynamic Range: Operates on 2-wire loops as defined an

ANSI T1.601-1992

Impedance: 135 Ohms

Switched Network Interface

3610 DSU: 8-pin non-keyed modular jack, USOC SJA11 U-Interface

Connector

3611 DSU: (One or two) 50-pin connector, pinout same as RJ21X

Transmit Interface

Signal Level : 13.5 dBm nominal over frequency band from 0 Hz to

80K Hz

Impedance: 135 Ohms

TDM/MCMP SPECIFICATIONS

Composite Speeds

TDM: 2,400; 4,800; 9,600; 19,200; 38,400; 56,000; and 64,000 bps

MCMP: 56,000 bps (48,000 usable for data)

Port Speeds

Synchronous terminal rates of: 1,200; 2,000; 2,400; 4,000; 7,200;

8,400; 9,600; 12,000; 14,400; 16,800; 18,000; 19,200; 28,800; 32,000;

38,400; 48,000; 56,000; and 64,000 bps (1,200 bps synchronous not

supported at 56,000 bps and 64,000 bps composite line rate)

 

Asynchronous Character Format

6, 7, 8, 9, or 10 bits; 1 or 2 stop bits

Elastic Storage Buffers

+/- 5 bits per second

Timing

DDS, internal (all ports), external (provided by selected port)

Digital Sharing Device (DSD)

Two groups up to six ports

Contention: RTS or ungoverned

MCMP (continued from page 3)

The TDM/MCMP option is supported by both the COMSPHERE 3610 standalone version and the COMSPHERE 3611 card version. The standalone

version provides 'Flex' function which allows each port to be configured as either RS232 or V.35 electrical. An expanded housing which provides

either one or five standard (DB25) connectors is required for either two- or six-port TDM/MCMP respectively. When V.35 electrical is selected, a DB25

to V.35 conversion cable is required for ports two through six. No conversion cable is required for port one because it is assigned to either an RS232D

or V.35 connector on the base DSU unit.

The card version supports two- or six-port TDM/MCMP with port one as either RS232D or V.35 connector and ports two through six as RS232. A

DB26 to V.35 connector cable is required when port one is assigned as a V.35 connection. Two-card slots are required to support TDM/MCMP in the

COMSPHERE 3000 Series Carrier. Thus, allowing a maximum of eight MCMP DSUs per carrier.

™

V.32bis Module

Analog Dial Module

Full or half-duplex data transmission via analog 2-wire DDD

Communications Line

2-wire PSTN line

Data Rate

Synchronous or asynchronous terminal rates of 2,400, 4,800, 9,600,

12,000 and 14,400 bps

PSTN Network Interface

3610 Standalone: 8-pin modular jack

Permissive: USOC RJ11C

Programmable: USOC RJ45S

3611 Carrier Card: 50-pin connector (one for slots 1-8, one for

slots 9-16)

Permissive: USOC RJ21X

Programmable: USOC RJ27X

SW56 Modules

Digital Dial Module (DM)

Full or half-duplex data transmission via: 4-wire Switched 56 Kbps or

2-wire Switched 56 Kbps, point-to-point

Communications Line

4-wire Switched 56 Kbps (AT&T ACCUNET, AT&T SDDN, and U. S.

Sprint VPN56) 2-wire Switched 56 Kbps (DataPath Compatible)

Data Rate

Synchronous or asynchronous terminal rate of 56,000 bps

4-Wire Switched 56 Kbps Network Interface

3610 Standalone: 8-pin modular jack USOC SJA56

3611 Carrier Card: 50-pin connector, USOC SJA57 (one for slots 1-8,

one for slots 9-16)

2-Wire Switched 56 Kbps Network Interface

3610 Standalone: SJA48 6-pin modular jack

3611 Carrier Card: 50-pin connector (Pinout same as RJ21X)

4

™

DIAL BACKUP MODULE (DBM) OPTIONS

The Dial Restoral option offers complete flexibility in all areas of user application recovery. Dial

Restoral provides automated, single-call, point-to-point and multipoint restoral over either the ISDN BRI

network, the two-wire Public Switched Telephone Network (PSTN), two-wire Switched 56 Digital

Network, or four-wire Switched 56 Digital Network.

Point-to-point restoral is accomplished using an integral Dial Backup Module (DBM). Dial line rates

supported for the ISDN BRI connection include full duplex, 56,000 or 64,000 bps operation. Dial line rates

supported for the PSTN connection include full duplex, 14,400 bps, 12,000 bps, 9,600 bps, 4,800 bps, or

2,400 bps operation.

The dial restoral connection can be controlled by the COMSPHERE 6700 Series NMS, the Shared

Diagnostic Control Panel (SDCP), or the COMSPHERE 3610 front panel. While in dial restoral mode, the

DSU automatically looks back to the digital facility and evaluates its health, switching back as soon as

service is restored. This automatic "lookback" feature helps minimize line costs by eliminating extended

long-distance line charges once the digital facility becomes operational again. Networks requiring continuous

availability can now attain uptime goals without dedicated around-the-clock staffing at the network

control center. An automated dial tone test during non-usage periods informs network operations if the

dial restoral circuit is disconnected. This eliminates the requirement for expensive and time-consuming

manual testing of dial restoral circuits by network operations.

In addition to its automatic restoral capabilities, the versatile Dial Restoral Option

features password and call-back security. When enabled, these security options prevent

unauthorized access and ensure integrity of the digital facility. A 10-number directory is capable of

selecting alternative destinations for the automated dial restoral process, as well as call-back

numbers for security.

Multipoint dial restoral is easy using the digital bridge feature of the card version TDM/MCMP option

and the DBMs, both of which are housed in the COMSPHERE 3000 Series Carrier. Each digital bridge

provides bridging for five remotes. Additional bridges can be interconnected to the first or primary bridge,

up to a maximum of six (including the primary bridge), to back-up a total of 25 remotes. The COMSPHERE

6700 Series NMS maintains complete control of the network during the multipoint restoral process.

DIAL BACKUP MODULE

• WIDE SELECTION OF AUTOMATIC DIAL

RESTORAL OPTIONS WITH ISDN BRI

(1B+D), ANALOG V.32bis (14.4 Kbps)

OR 2- OR 4-WIRE SW56

• UNIQUE “DIAL TONE” MONITORING

TO ENSURE AVAILABILITY OF RESTORAL

CIRCUIT

• AUTOMATIC RETURN TO DIGITAL LEASED

LINE AFTER RESUMING NORMAL SERVICE

5

3610 back panel

3610 with TDM back panel

 

O P T I O N A L

F E A T U R E S

DIG-DS36-3-0398

COMSPHERE is a registered trademark of Paradyne Corporation. PARADYNE and ANALYSIS are trademarks of Paradyne

Corporation. All other products or services mentioned are the trademarks, service marks, registered trademarks, or registered

service marks of their respective owners.

Standalone DSU 3610-A4-001

Nest DSU 3611-B4-001

COMSPHERE 3000 Carrier

with 115 VAC Power 3000-B1-201

COMSPHERE 3000 Carrier Options:

Fan Module (115 VAC) 3000-F1-007

Shared Diagnostic Control Panel 3000-F1-001

(with ribbon cable)

Shared Diagnostic Unit (SDU) 3000-F1-002

Rear Connector Plate 3000-F1-021

Filler Panel 3000-F1-008

NMS EIA-232 Interface Connector 6821-F1-513

Remote-site Adapter Cables 6821-F1-518

(M6AYand M6BK - 7' and 5' respectively)

Network Adapter Cable 1.5' 3600-F2-503

50-pin to eight 8-pin Modular 3600-F2-503

Network Interfaces

(DSU/JM8 lease) Adapter for

Digital or Leased Lines

ASCII Interface Cable 10' 3600-F3-504

(DSU Control Channel RJ11

to DB25 DTE connector)

S/A DSU with 2 port

TDM/MCMP ‘Flex’ 3610-A4-020

S/A DSU with 6 port

TDM/MCMP ‘Flex’ 3610-A4-024

Nest DSU with 6 port TDM/MCMP 3611-B4-003

V.35 Interconnect Cable for card 3600-F3-500

version only

Field upgrade options to existing DSUs

S/A DSU upgrade to 2 port 3600-F3-209

TDM/MCMP 'Flex' Field Install

S/A DSU upgrade to 6 port 3600-F3-213

TDM/MCMP 'Flex' Field Install

NEST DSU upgrade to 6 port 3600-F4-205

TDM/MCMP Field Install

Cables

V.35 Interconnect Cable for 3600-F3-500

card version only (18")

DSUs with integrated dial restoral modules:

S/A R3 DSU w/ ISDN BRI DBU 3610-A4-026

Nest R3 DSU w/ISDN BRI DBU 3611-B4-026

S/A R3 DSU w/14.4 Kbps 3610-A4-002

analog DBU

Nest R3 DSU w/14.4 Kbps 3611-B4-002

analog DBU

Standalone R3 DSU 3610-A4-014

w/4W-SW56 DBU

Nest R3 DSU w/4W-SW56 DBU 3611-B4-014

Standalone R3 DSU 3610-A4-012

w/2W-SW56 DBU

Nest R3 DSU w/2W-SW56 DBU 3611-B4-012

Card version dial restoral modules for

multipoint circuits for use with TDM card

version optioned as digital bridge:

ISDN BRI DBM-I M/P Dial Restoral 3611-B4-016

14.4 Kbps analog DBM-V 3611-B4-005

M/P Dial Restoral

4W-SW56 DBM-S M/P Dial Restoral 3611-B4-008

2W-SW56 DBM-D M/P Dial Restoral 3611-B4-010

Field upgrade options to existing DSUs

ISDN BRI Dial Restoral Field Install 3600-F3-026

14.4 Kbps analog Dial 3600-F3-201

Restoral Field Install

4W-SW56 Dial Restoral Field Install 3600-F3-056

2W-SW56 Dial Restoral Field Install 3600-F3-256

Network Interface Module (NIM) for use with

COMSPHERE 3000 Carrier and 3611 card version

DSU:

Permissive for ISDN BRI, 14.4 Kbps 3000-F1-003

and 2-wire SW56 Kbps

(1 per 8 carrier slots)

Programmable for 14.4 Kbps 3000-F1-004

(1 per 8 carrier slots)

For 4-wire SW56 Kbps 3000-F1-025

(1 per 8 carrier slots)

50-pin mass termination cable 10' - 3000 F1-013

(1 per NIM) Permissive 30' - 3000-F1-014

RJ21X

Programmable RJ27X Telephone Cables for use

with Standalone COMSPHERE 3610 Series DSU

3610 Series DSU Modular 7' - 4400-F1-531

RJ11C (6-pin) Permissive 14' - 3600-F3-503

DDD (PSTN) plug 25' - 4400-F1-533

Modular RJ45S (8-pin) 7' - 4400-F1-541

Programmable DDD 14' - 4400-F1-543

(PSTN) plug 25' - 4400-F1-544

Telephone Cords for use with Standalone

COMSPHERE 3610 Series DSU

Modular RJ11C (6-pin) 14' - 3600-F3-503

(for 2-wire SW56 Kbps)

Modular RJ45S (8-pin) 14' - 3600-F3-501

(for 4-wire SW56 Kbps) 25' - 3600-F3-502

CONTROLS AND INDICATORS

The COMSPHERE 3610 Diagnostic Control Panel

(DCP), 3611 face plate, and the optional SDCP

feature a full complement of controls and indicators.

They incorporate a menu-driven, Englishlanguage

display to monitor on-line performance,

change operating modes, and control local and

remote testing.

Indicators

These display signal activity at the DTE/DSU

interface and provide operational status

information.

Alpha-Numeric Display

The two-line by 16-character LCD on the front

panel displays status information and serves as

the primary user interface for equipment setup,

reconfiguration, and diagnostic operation.

Controls

Function keys (F1, F2, etc.) are used to select

options and move within the menu structure for

equipment configuration, testing and similar

operations.

Basic DSU Indicators

TXD/103 - Transmit data

RXD/104 - Receive data

RTS/105 - Request-to-send

CTS/106 - Clear-to-send

DSR/107 - Data set ready

DTR/108 - Data terminal ready

LSD/109 - Line signal detect

DSU Status Indicators

OK - Normal operation

Alarm - Fault in DSU, DBM or facility;

streaming DTE

Test - Test in progress

Dial - DBM active

Front Panel - Indicates card selected by SDCP

(3611 only)

SDCP- Controls and Indicators

Select - Provides SDCP selection of carrier DSU

Bck Up - Indicates selected DSU in dial backup

mode

DCP Controls

– Moves up one menu level

– Moves one position to left on menu

– Moves to top of menu

– Moves one position to right on menu

F1, F2, F3 - Multifunction keys defined by display

line located above them

 

 

 

Send mail to rb@rbdatasys.com with questions or comments about this web site.