Asynchronous Character Format
6, 7, 8, 9,
or 10 bits; 1 or 2 stop bits
Elastic
Storage Buffers
+/- 5 bits
per second
Timing
DDS,
internal (all ports), external (provided by selected port)
Digital
Sharing Device (DSD)
Two groups
up to six ports
Contention:
RTS or ungoverned
MCMP
(continued from page 3)
The TDM/MCMP
option is supported by both the COMSPHERE 3610 standalone version and the
COMSPHERE 3611 card version. The standalone
version
provides 'Flex' function which allows each port to be configured as either
RS232 or V.35 electrical. An expanded housing which provides
either one
or five standard (DB25) connectors is required for either two- or six-port
TDM/MCMP respectively. When V.35 electrical is selected, a DB25
to V.35
conversion cable is required for ports two through six. No conversion cable
is required for port one because it is assigned to either an RS232D
or V.35
connector on the base DSU unit.
The card
version supports two- or six-port TDM/MCMP with port one as either RS232D or
V.35 connector and ports two through six as RS232. A
DB26 to
V.35 connector cable is required when port one is assigned as a V.35
connection. Two-card slots are required to support TDM/MCMP in the
COMSPHERE
3000 Series Carrier. Thus, allowing a maximum of eight MCMP DSUs per
carrier.
V.32bis
Module
Analog Dial
Module
Full or
half-duplex data transmission via analog 2-wire DDD
Communications Line
2-wire PSTN
line
Data Rate
Synchronous
or asynchronous terminal rates of 2,400, 4,800, 9,600,
12,000 and
14,400 bps
PSTN
Network Interface
3610
Standalone: 8-pin modular jack
Permissive:
USOC RJ11C
Programmable: USOC RJ45S
3611
Carrier Card: 50-pin connector (one for slots 1-8, one for
slots 9-16)
Permissive:
USOC RJ21X
Programmable: USOC RJ27X
SW56
Modules
Digital
Dial Module (DM)
Full or
half-duplex data transmission via: 4-wire Switched 56 Kbps or
2-wire
Switched 56 Kbps, point-to-point
Communications Line
4-wire
Switched 56 Kbps (AT&T ACCUNET, AT&T SDDN, and U. S.
Sprint
VPN56) 2-wire Switched 56 Kbps (DataPath Compatible)
Data Rate
Synchronous
or asynchronous terminal rate of 56,000 bps
4-Wire
Switched 56 Kbps Network Interface
3610
Standalone: 8-pin modular jack USOC SJA56
3611
Carrier Card: 50-pin connector, USOC SJA57 (one for slots 1-8,
one for
slots 9-16)
2-Wire
Switched 56 Kbps Network Interface
3610
Standalone: SJA48 6-pin modular jack
3611
Carrier Card: 50-pin connector (Pinout same as RJ21X)
4
DIAL
BACKUP MODULE (DBM) OPTIONS
The Dial
Restoral option offers complete flexibility in all areas of user application
recovery. Dial
Restoral
provides automated, single-call, point-to-point and multipoint restoral over
either the ISDN BRI
network,
the two-wire Public Switched Telephone Network (PSTN), two-wire Switched 56
Digital
Network, or
four-wire Switched 56 Digital Network.
Point-to-point restoral is accomplished using an integral Dial Backup Module
(DBM). Dial line rates
supported
for the ISDN BRI connection include full duplex, 56,000 or 64,000 bps
operation. Dial line rates
supported
for the PSTN connection include full duplex, 14,400 bps, 12,000 bps, 9,600
bps, 4,800 bps, or
2,400 bps
operation.
The dial
restoral connection can be controlled by the COMSPHERE 6700 Series NMS, the
Shared
Diagnostic
Control Panel (SDCP), or the COMSPHERE 3610 front panel. While in dial
restoral mode, the
DSU
automatically looks back to the digital facility and evaluates its health,
switching back as soon as
service is
restored. This automatic "lookback" feature helps minimize line costs by
eliminating extended
long-distance line charges once the digital facility becomes operational
again. Networks requiring continuous
availability can now attain uptime goals without dedicated around-the-clock
staffing at the network
control
center. An automated dial tone test during non-usage periods informs network
operations if the
dial
restoral circuit is disconnected. This eliminates the requirement for
expensive and time-consuming
manual
testing of dial restoral circuits by network operations.
In addition
to its automatic restoral capabilities, the versatile Dial Restoral Option
features
password and call-back security. When enabled, these security options
prevent
unauthorized access and ensure integrity of the digital facility. A
10-number directory is capable of
selecting
alternative destinations for the automated dial restoral process, as well as
call-back
numbers for
security.
Multipoint
dial restoral is easy using the digital bridge feature of the card version
TDM/MCMP option
and the
DBMs, both of which are housed in the COMSPHERE 3000 Series Carrier. Each
digital bridge
provides
bridging for five remotes. Additional bridges can be interconnected to the
first or primary bridge,
up to a
maximum of six (including the primary bridge), to back-up a total of 25
remotes. The COMSPHERE
6700 Series
NMS maintains complete control of the network during the multipoint restoral
process.
DIAL
BACKUP MODULE
WIDE
SELECTION OF AUTOMATIC DIAL
RESTORAL
OPTIONS WITH ISDN BRI
(1B+D),
ANALOG V.32bis (14.4 Kbps)
OR 2- OR
4-WIRE SW56
UNIQUE
DIAL TONE MONITORING
TO ENSURE
AVAILABILITY OF RESTORAL
CIRCUIT
AUTOMATIC
RETURN TO DIGITAL LEASED
LINE AFTER
RESUMING NORMAL SERVICE
5
3610 back
panel
3610 with
TDM back panel
O P T I
O N A L
F E A T
U R E S
DIG-DS36-3-0398
COMSPHERE
is a registered trademark of Paradyne Corporation. PARADYNE and ANALYSIS are
trademarks of Paradyne
Corporation. All other products or services mentioned are the trademarks,
service marks, registered trademarks, or registered
service
marks of their respective owners.
Standalone
DSU 3610-A4-001
Nest DSU
3611-B4-001
COMSPHERE
3000 Carrier
with 115
VAC Power 3000-B1-201
COMSPHERE
3000 Carrier Options:
Fan Module
(115 VAC) 3000-F1-007
Shared
Diagnostic Control Panel 3000-F1-001
(with
ribbon cable)
Shared
Diagnostic Unit (SDU) 3000-F1-002
Rear
Connector Plate 3000-F1-021
Filler
Panel 3000-F1-008
NMS EIA-232
Interface Connector 6821-F1-513
Remote-site
Adapter Cables 6821-F1-518
(M6AYand
M6BK - 7' and 5' respectively)
Network
Adapter Cable 1.5' 3600-F2-503
50-pin to
eight 8-pin Modular 3600-F2-503
Network
Interfaces
(DSU/JM8
lease) Adapter for
Digital or
Leased Lines
ASCII
Interface Cable 10' 3600-F3-504
(DSU
Control Channel RJ11
to DB25 DTE
connector)
S/A DSU
with 2 port
TDM/MCMP
Flex 3610-A4-020
S/A DSU
with 6 port
TDM/MCMP
Flex 3610-A4-024
Nest DSU
with 6 port TDM/MCMP 3611-B4-003
V.35
Interconnect Cable for card 3600-F3-500
version
only
Field
upgrade options to existing DSUs
S/A DSU
upgrade to 2 port 3600-F3-209
TDM/MCMP
'Flex' Field Install
S/A DSU
upgrade to 6 port 3600-F3-213
TDM/MCMP
'Flex' Field Install
NEST DSU
upgrade to 6 port 3600-F4-205
TDM/MCMP
Field Install
Cables
V.35
Interconnect Cable for 3600-F3-500
card
version only (18")
DSUs with
integrated dial restoral modules:
S/A R3 DSU
w/ ISDN BRI DBU 3610-A4-026
Nest R3 DSU
w/ISDN BRI DBU 3611-B4-026
S/A R3 DSU
w/14.4 Kbps 3610-A4-002
analog DBU
Nest R3 DSU
w/14.4 Kbps 3611-B4-002
analog DBU
Standalone
R3 DSU 3610-A4-014
w/4W-SW56
DBU
Nest R3 DSU
w/4W-SW56 DBU 3611-B4-014
Standalone
R3 DSU 3610-A4-012
w/2W-SW56
DBU
Nest R3 DSU
w/2W-SW56 DBU 3611-B4-012
Card
version dial restoral modules for
multipoint
circuits for use with TDM card
version
optioned as digital bridge:
ISDN BRI
DBM-I M/P Dial Restoral 3611-B4-016
14.4 Kbps
analog DBM-V 3611-B4-005
M/P Dial
Restoral
4W-SW56 DBM-S
M/P Dial Restoral 3611-B4-008
2W-SW56 DBM-D
M/P Dial Restoral 3611-B4-010
Field
upgrade options to existing DSUs
ISDN BRI
Dial Restoral Field Install 3600-F3-026
14.4 Kbps
analog Dial 3600-F3-201
Restoral
Field Install
4W-SW56
Dial Restoral Field Install 3600-F3-056
2W-SW56
Dial Restoral Field Install 3600-F3-256
Network
Interface Module (NIM) for use with
COMSPHERE
3000 Carrier and 3611 card version
DSU:
Permissive
for ISDN BRI, 14.4 Kbps 3000-F1-003
and 2-wire
SW56 Kbps
(1 per 8
carrier slots)
Programmable for 14.4 Kbps 3000-F1-004
(1 per 8
carrier slots)
For 4-wire
SW56 Kbps 3000-F1-025
(1 per 8
carrier slots)
50-pin mass
termination cable 10' - 3000 F1-013
(1 per NIM)
Permissive 30' - 3000-F1-014
RJ21X
Programmable RJ27X Telephone Cables for use
with
Standalone COMSPHERE 3610 Series DSU
3610 Series
DSU Modular 7' - 4400-F1-531
RJ11C
(6-pin) Permissive 14' - 3600-F3-503
DDD (PSTN)
plug 25' - 4400-F1-533
Modular
RJ45S (8-pin) 7' - 4400-F1-541
Programmable DDD 14' - 4400-F1-543
(PSTN) plug
25' - 4400-F1-544
Telephone
Cords for use with Standalone
COMSPHERE
3610 Series DSU
Modular
RJ11C (6-pin) 14' - 3600-F3-503
(for 2-wire
SW56 Kbps)
Modular
RJ45S (8-pin) 14' - 3600-F3-501
(for 4-wire
SW56 Kbps) 25' - 3600-F3-502
CONTROLS
AND INDICATORS
The
COMSPHERE 3610 Diagnostic Control Panel
(DCP), 3611
face plate, and the optional SDCP
feature a
full complement of controls and indicators.
They
incorporate a menu-driven, Englishlanguage
display to
monitor on-line performance,
change
operating modes, and control local and
remote
testing.
Indicators
These
display signal activity at the DTE/DSU
interface
and provide operational status
information.
Alpha-Numeric Display
The
two-line by 16-character LCD on the front
panel
displays status information and serves as
the primary
user interface for equipment setup,
reconfiguration, and diagnostic operation.
Controls
Function
keys (F1, F2, etc.) are used to select
options and
move within the menu structure for
equipment
configuration, testing and similar
operations.
Basic DSU
Indicators
TXD/103 -
Transmit data
RXD/104 -
Receive data
RTS/105 -
Request-to-send
CTS/106 -
Clear-to-send
DSR/107 -
Data set ready
DTR/108 -
Data terminal ready
LSD/109 -
Line signal detect
DSU Status
Indicators
OK - Normal
operation
Alarm -
Fault in DSU, DBM or facility;
streaming
DTE
Test - Test
in progress
Dial - DBM
active
Front Panel
- Indicates card selected by SDCP
(3611 only)
SDCP-
Controls and Indicators
Select -
Provides SDCP selection of carrier DSU
Bck Up -
Indicates selected DSU in dial backup
mode
DCP
Controls
Moves up
one menu level
Moves one
position to left on menu
Moves to
top of menu
Moves one
position to right on menu
F1, F2, F3
- Multifunction keys defined by display
line
located above them